Case Studies

 


 

SKIN HEALTH SPA – NANTWICH

 


 

Skin health Spa - Air Conditioning Install
Air conditioning install - Skin health spa

INSTALLATION OF TOSHIBA RAV SM 804KRT

We were approached by a National Health Spa company to find a way to counteract the heat given off from a laser machine used for hair removal.

The brief was to reduce the high temperatures in the room for both the client and staff operating in the area, whilst have little effect on the tranquil atmosphere created in the room.

We installed a Toshiba RAV SM 804KRT Wall mount system to create the correct comfort level and right ambience

 


 

Bargain Food & Freezer – Chester

 


 

Bespoke Toshiba air conditioning multiple unit
Chester Bespoke Toshiba Air Cont Multiple Unit

Installation Of Toshiba Air Conditioning

This project was a challenge!

Our client was opening a frozen food centre with over 40 refrigerated cabinets, all generating heat.

Our brief was to combat this heat and provide a comfortable environment for staff and customers alike.

We had to install four cassette indoor units to give the correct air distribution and full coverage of the retail area. these were backed up by two 28Kw condensing units operating on 3 phase electricity.

The refrigeration pipe run was some 40 metres and so careful consideration was given to the route the pipe work took and to allow for refrigeration pressure drop when selecting equipment.

we installed two systems of 28kw under budget and completed within 5 working days

 


 

The Red Fox – On The Wirral

 


 

Wirral Bespoke Chiller freezer room install

Installation of cold room

Our brief was to install a cold room measuring 4.5m long x 2.8m wide but with a reduced  of 2 m external!

The cold room was manufactured by ISD cold rooms of worcester and installed underground in a refurbished kitchen which was the former nightclub of the pub. The refrigeration system was installed remotely with a pipe run on 15m.

 


 

Crewe Alex Football Club – Crewe

 


 

Crewe Alex FC - Bespoke Cellar Cooling Outdoor unit
Crewe Alex FC - Bespoke Cellar Cooling

Installation of cellar cooling

Our brief was to provide cellar cooling for a over sized cellar.

we first instructed our client the reduce the room height from the existing 4.5m high to a more acceptable 2.7m. As a result this would prevent the cellar cooling system from trying to cool the “dead area” above the 2.7m height used.

After the ceiling height was reduced we were able to select a system some 4 sizes smaller in capacity, resulting in massive cost savings!

The cellar cooling was to replace a system that had been operating (with the high wasted ceiling space) for 10 years. we chose a Thermofrost Cryo system to allow for the large volume of sea to be cooled and the 50m pipe run for the refrigeration pipe work.

 


 

Bargain Food & Freezer Р chester

 


 

Chester Apline Multideck Install

Installation of Multideck

We are requested to provide over 6m of refrigerated display for our client who was looking to meet the demands of their lunch time trade “meal deals”

we supplied 2 x 3m alpine multi decks that were wheeled into place and multiplexed together to form the 6m run of refrigerated display required.